product-image

PC20

The Power Management Unit is the brain of the system. It receives requests from switches or keypads and handles these commands based on the current state of the system. The output may be the activation/deactivation of a circuit or starting a timer function. The PowerCore then sends status data from system to keypads to turn on/off the LED indicators and backlighting.

DOWNLOAD DATASHEET

ELECTRICAL FEATURES

  • 12V or 24V nominal input voltage

  • 150 Ampere total PME input current carrying capability

  • 22 switched circuits that include:
    – Momentary, toggle, and time-out functions.
    – Pulse-width modulation of output voltage for dimming capability.
    – 5 circuits rated up to 20A maximum continuous load, 17 circuits rated up to 15A.
    – 4 complete H-Bridge circuits for driving reversible motors.

  • Parallelable output increases current rating.

  • An electronic circuit breaker protects every circuits. The current ratio for each circuit can be set independently.

  • Remote reset of any output circuitry fault through keypad.

  • Input undervoltage lock down.

SPECIAL FEATURES

  • CAN-bus compatible (CANopen/J1939 compliance available)

  • Field programmability of electrical functions and current limit trip points available to authorized OEMs and Value-Added Resellers (VARs)

  • 4-circuit bypass for essential functions

  • Up to two N.O. relay contact (optional)

SPECIFICATIONS FOR PC20 SOLID STATE POWERCORE MANAGEMENT ENCLOSURE

ELECTRICAL

Supply Voltage 12V and 24V Nominal Voltage (8-32VDC)
Standby Current <30mA per PME
Load current Max 20A
Input current 15DA max
Communication BUS RS-485 between keypad and PME
CAN Bus Slave
Circuit protection electronic overcurrent protection and automotive mini blade fuse

MECHANICAL

Connector Molex MX150L #19427-0032 & 19429-0040 & 19429-0039
Mating connector Molex MX150L #19418-0030 & 19418-0004 & 19418-0027
Housing ALLOY 6060 and ZA4C1
Seal TPV 8211-75
Power stud Amphenol surlock plus series
PC Board 1,6mm thick, Nema Grade FR-4, Double clad with 3oz copper

ENVIRONMENTAL

Operating Temperature -20°C to +85°C
Storage Temperature -40°C to +85°C
Humidity 0 to 98% (no condensation)
Ingress protection Rating IP65

FEATURES

Circuits 22
Size mm connectors incl. 230 x 170 x 86
Remote current trip reset Standard on all outputs
System reset Optional
Status indicator Standard
By-pass 4 outputs
Low volt sense & lock down Optional
Pull down 9 outputs
“H” Bridge capability 4 complete “H” bridges available
Level sense input 8 inputs
Dimming/PWM Features Available on 10 outputs
Circuit status monitoring Optional
Field re-programmable Optional
External status communication on the bus Optional
N.O. relay contact Optional

Technical schemes